2,350 research outputs found

    Analysis and correction of the magnetic field effects in the Hybrid Photo-Detectors of the RICH2 Ring Imaging Cherenkov detector of LHCb

    Full text link
    The Ring Imaging Cherenkov detectors of the LHCb experiment at the Large Hadron Collider at CERN are equipped with Hybrid Photo-Detectors. These vacuum photo-detectors are affected by the stray magnetic field of the LHCb magnet, which degrades their imaging properties. This effect increases the error on the Cherenkov angle measurement and would reduce the particle identification capabilities of LHCb. A system has been developed for the RICH2 Ring Imaging Cherenkov detector to perform a detailed characterisation of the magnetic distortion effects. It is described, along with the methods implemented to correct for these effects, restoring the optimal resolution.Comment: 16 pages, 11 figure

    TORCH: A Cherenkov Based Time-of-Flight Detector

    Get PDF
    TORCH is a novel high-precision time-of-flight detector suitable for large area applications and covering the momentum range up to 10 GeV/c. The concept uses Cherenkov photons produced in a fused silica radiator which are propagated to focussing optics coupled to fast photodetectors. For this purpose, custom MCP-PMTs are being produced in collaboration with industrial partners. The development is divided into three phases. Phase 1 addresses the lifetime requirements for TORCH, Phase 2 will customize the MCP-PMT granularity and Phase 3 will deliver prototypes that meet the TORCH requirements. Phase 1 devices have been successfully delivered and initial tests show stable gain performance for integrated anode current >5 C/cm2 and a single photon time resolution of ≀ 30 ps. Initial simulations indicate the single photon timing resolution of the TORCH detector will be ∌70 ps

    Beam tests of a large-scale TORCH time-of-flight demonstrator

    Full text link
    The TORCH time-of-flight detector is designed to provide particle identification in the momentum range 2-10 GeV/c over large areas. The detector exploits prompt Cherenkov light produced by charged particles traversing a 10 mm thick quartz plate. The photons propagate via total internal reflection and are focused onto a detector plane comprising position-sensitive Micro-Channel Plate Photo-Multiplier Tubes (MCP-PMT) detectors. The goal is to achieve a single-photon timing resolution of 70 ps, giving a timing precision of 15 ps per charged particle by combining the information from around 30 detected photons. The MCP-PMT detectors have been developed with a commercial partner (Photek Ltd, UK), leading to the delivery of a square tube of active area 53 ×\times 53mm2^2 with a granularity of 8 ×\times 128 pixels equivalent. A large-scale demonstrator of TORCH, having a quartz plate of dimensions 660 ×\times 1250 ×\times 10 mm3^3 and read out by a pair of MCP-PMTs with custom readout electronics, has been verified in a test beam campaign at the CERN PS. Preliminary results indicate that the required performance is close to being achieved. The anticipated performance of a full-scale TORCH detector at the LHCb experiment is presented.Comment: 12 pages, 7 figures, Paper submitted to Nuclear Instruments & Methods in Physics Research, Section A - Special Issue VCI 201

    TORCH: A Cherenkov Based Time-of-Flight Detector

    Get PDF
    TORCH is a novel high-precision time-of-flight detector suitable for large area applications and covering the momentum range up to 10 GeV/c. The concept uses Cherenkov photons produced in a fused silica radiator which are propagated to focussing optics coupled to fast photodetectors. For this purpose, custom MCP-PMTs are being produced in collaboration with industrial partners. The development is divided into three phases. Phase 1 addresses the lifetime requirements for TORCH, Phase 2 will customize the MCP-PMT granularity and Phase 3 will deliver prototypes that meet the TORCH requirements. Phase 1 devices have been successfully delivered and initial tests show stable gain performance for integrated anode current >5 C/cm2 and a single photon time resolution of ≀ 30 ps. Initial simulations indicate the single photon timing resolution of the TORCH detector will be ∌70 ps

    Test-beam and laboratory characterisation of the TORCH prototype detector

    Get PDF
    The TORCH time-of-flight (TOF) detector is being developed to provide particle identification up to a momentum of 10 GeV/c over a flight distance of 10 m. It has a DIRC-like construction with View the MathML source10mm thick synthetic amorphous fused-silica plates as a Cherenkov radiator. Photons propagate by total internal reflection to the plate periphery where they are focused onto an array of customised position-sensitive micro-channel plate (MCP) detectors. The goal is to achieve a 15 ps time-of-flight resolution per incident particle by combining arrival times from multiple photons. The MCPs have pixels of effective size 0.4 mm×6.6 mm2 in the vertical and horizontal directions, respectively, by incorporating a novel charge-sharing technique to improve the spatial resolution to better than the pitch of the readout anodes. Prototype photon detectors and readout electronics have been tested and calibrated in the laboratory. Preliminary results from testbeam measurements of a prototype TORCH detector are also presented

    Some remarks on PM2.5

    Get PDF
    Since 1970, the General Physics Department of «UniversitĂ  degli Studi di Torino» has carried out a project research, on inorganic solid particulate matter. The special issue of Annals of Geophysics, published for Professor Giorgio Fiocco’s 70th birthday, gives us the possibility to make some important remarks on this topic, focusing on PM2.5. This has been possible using all the old and new experimental data of the measures made by the authors of this paper since 1970

    The TORCH time-of-flight detector

    Get PDF
    AbstractThe TORCH time-of-flight detector is being developed to provide particle identification between 2 and 10GeV/c momentum over a flight distance of 10m. TORCH is designed for large-area coverage, up to 30m2, and has a DIRC-like construction. The goal is to achieve a 15ps time-of-flight resolution per incident particle by combining arrival times from multiple Cherenkov photons produced within quartz radiator plates of 10mm thickness. A four-year R&D programme is underway with an industrial partner (Photek, UK) to produce 53×53mm2 Micro-Channel Plate (MCP) detectors for the TORCH application. The MCP-PMT will provide a timing accuracy of 40ps per photon and it will have a lifetime of up to at least 5Ccm−2 of integrated anode charge by utilizing an Atomic Layer Deposition (ALD) coating. The MCP will be read out using charge division with customised electronics incorporating the NINO chipset. Laboratory results on prototype MCPs are presented. The construction of a prototype TORCH module and its simulated performance are also described

    TORCH pattern recognition and particle identification performance

    Get PDF
    The TORCH detector aims to provide K/π (K/p) separation up to a momentum of about 10 (15) [Formula presented] by measuring their time-of-flight at the LHCb detector. Prompt Cherenkov photons are produced in a quartz radiator bar of 10 mm thickness, and propagated via total internal reflection to the periphery of the detector, where they are focused onto an array of microchannel plate photomultipliers that measure the photon arrival time and position. Pattern recognition techniques are used to compare the likelihood that the detector image is due to a given particle hypothesis. Good performance is obtained even for very high detector occupancies

    Study of B−→DK−π+π−B^{-}\to DK^-\pi^+\pi^- and B−→Dπ−π+π−B^-\to D\pi^-\pi^+\pi^- decays and determination of the CKM angle Îł\gamma

    Get PDF
    We report a study of the suppressed B−→DK−π+π−B^-\to DK^-\pi^+\pi^- and favored B−→Dπ−π+π−B^-\to D\pi^-\pi^+\pi^- decays, where the neutral DD meson is detected through its decays to the K∓π±K^{\mp}\pi^{\pm} and CP-even K+K−K^+K^- and π+π−\pi^+\pi^- final states. The measurement is carried out using a proton-proton collision data sample collected by the LHCb experiment, corresponding to an integrated luminosity of 3.0~fb−1^{-1}. We observe the first significant signals in the CP-even final states of the DD meson for both the suppressed B−→DK−π+π−B^-\to DK^-\pi^+\pi^- and favored B−→Dπ−π+π−B^-\to D\pi^-\pi^+\pi^- modes, as well as in the doubly Cabibbo-suppressed D→K+π−D\to K^+\pi^- final state of the B−→Dπ−π+π−B^-\to D\pi^-\pi^+\pi^- decay. Evidence for the ADS suppressed decay B−→DK−π+π−B^{-}\to DK^-\pi^+\pi^-, with D→K+π−D\to K^+\pi^-, is also presented. From the observed yields in the B−→DK−π+π−B^-\to DK^-\pi^+\pi^-, B−→Dπ−π+π−B^-\to D\pi^-\pi^+\pi^- and their charge conjugate decay modes, we measure the value of the weak phase to be Îł=(74−19+20)o\gamma=(74^{+20}_{-19})^{\rm o}. This is one of the most precise single-measurement determinations of Îł\gamma to date.Comment: 22 pages, 9 figures; All figures and tables, along with any supplementary material and additional information, are available at https://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-PAPER-2015-020.htm
    • 

    corecore